floor deck design guide - ASC Steel Deck

Composite deck. 2 inch nominal depth, 36 inch coverage. 7 foot to 12 foot Optimal Span Range. No Acustadek? Option. Least steel weight per square foot floor deck. Meets SDI 2x12 inch standard profile requirements .. the structural capacity of the deck. On projects where the deck will be exposed to view after

Get Price

Metal Deck Systems - Composite Floor Deck - 2.0" Composite Floor

Composite deck slabs are single span condition with the deck serving as the positive reinforcing for the slab. Research has shown that the presence of shear studs for composite beam design influences the moment capacity of the composite deck system. When the number of shear studs present are of sufficient quantity, the

Get Price

Composite Steel Floor Deck - Slabs - Steel Deck Institute

Composite Steel Floor Deck - Slabs. C - 2011 Standard for. AMERICAN NATIONAL STANDARDS INSTITUTE/ STEEL DECK INSTITUTE. STEEL DECK. INSTITUTE s. ?. 5. 3. When the ductility of the steel used for deck, measured over a two-inch (50 mm) gage length, is less than 10%, the ability of the steel to be formed

Get Price

Example Calculations - Canam Construction

shown on pages 42 and 43 of our Design Manual and Catalog of Steel Deck Products. Example Problems For Concentrated Loads. Example 1: Point Load. This problem is designed to demonstrate how to check the ability of a composite slab to carry a. 3000 lb point load over an area of 4.5" x 4.5" occurring anywhere in the

Get Price

Composite Steel Floor Deck-Slabs - Steel Deck Institute

deducting the weight of the slab and the deck from the total load capacity. Unless composite deck-slabs are designed for continuity, slabs shall be assumed to act on simple spans. Commentary: Most published live load tables are based on simple span analysis of the composite system; that is, a continuous slab is assumed

Get Price

Steel Deck Institute, Inc. Design Manual for Composite Decks, Form

Jan 1, 1987 The deck capacity as a form and the load capacity of the composite deck/slab system are not increased by staggering the end laps; layout and erec- tion costs are increased. 4.4 Differential Deflection: Shall be controlled by fas- tening together sidelaps of floor deck units as recom- mended by the steel deck.

Get Price

Steel Deck - Canam Construction

Canam is a leading producer of steel deck, short and long span steel joists and joist girders. United Steel Deck, Inc. (USD) was established in 1968 as a manufacturer of metal roof deck and floor form. The product line was expanded to include composite floor deck, deep roof deck, cellular roof and floor deck and metal wall

Get Price

Shear-bond Capacity of Composite Slabs - Scholars' Mine

This paper presents an ultimate shear-bond equation for composite slabs failing in shear-bond. The equation is based on recent experimental evi- dence of composite slabs exhibiting early end slip prior to ultimate load, and contains the steel deck thickness as a parameter which other existing equa- tions do not.

Get Price

ESR-3168 - Company, Inc. - ICC-ES

from the board end and sides. The allowable fastener head pull-through capacity for the screws is 237 lbf (1054 N) per fastener. Multiple joists or blocking must be used to provide adequate surface for fastener embedment at board ends. 5.0 CONDITIONS OF USE. The ? composite deck boards described in this report.

Get Price

Product Details